Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Pump common suction pump one, the pump is not suction Second, the motor speed is not enough Three, the pump vibration or noise Strong pump common faults First, the pump does not absorb the oil causes: 1, the suction pipe blocked or leak 2, the inhalation height exceeds Allow suction vacuum height 3, the motor reverses 4, the medium viscosity is too large 2, the flow rate down reason: 1, suction pipe blockage or leakage 2, screw and pump sleeve wear 3, safety valve spring is too loose or valve and valve seat Inaccurate contact 4, the motor speed is not enough 3, the pump vibration or noise: the pump is not installed or the pump installed too high; motor ball bearing damage; pump spindle bending or spindle with the motor is not the heart, not parallel and so on. Treatment: install a steady pump or reduce the installation height of the pump; replace the motor ball bearings; correct the bending of the pump shaft or adjust the relative position of the pump and the motor. Fourth, a large number of mechanical seal leakage reasons: 1, the assembly position is not 2, the sealing gland is not flat 3, moving ring or static seal surface bump 4, moving ring or static ring seal damage Fifth, the shaft or motor bearings Overheating: Causes: lack of lubricant or bearing rupture. Approach: add oil or replace the bearing.
November 15, 2023
November 10, 2023
Mail an Lieferanten
November 15, 2023
November 10, 2023
October 18, 2022
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.